IBP Medical
If quality matters - IBP Medical
 
 
 
LabCon-C Calibration Systems           Please contact us to discuss your solution!
 
 
 
 


 

 

Flow Calibration System

For meters and sensors used in biomedical, laboratory and environmental applications

Key Features
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .. . . . . . . . . . . . . .
 
Complete ready to go solution
Automatic flow generation
Calibration with internal sensor or with external calibration flask
   


Flow Generation

The LabCon UPHD-Module handles and prepares the RO-Water used in the calibration of reference meters and sensors.

Range from 100 to 2000 ml/min
Degassing of water in water tank

Reference Sensors

The UFHD-Module has two references.  A 5000 ml calibration flask and an internal high accuracy flow sensor.

Different calibration operation mode
Calibration against calibration flask
Calibration against internal sensor
Calibration of internal sensor against calibration flask


Control Software

The software allows to select the flow and provides messages with the status of the calibration process.

After starting the calibration procedure
the user interface looks as follows.
From the detected sensor the readings will be shown.

 

 

 

Calibration Equipment Flow

 

 

 

 

 
Automated Calibration Flask


 


The automated calibration flask allows
an easy and precise calibration procedure.

The unit consists of a 5000 ml calibration
flask and the Level Control Unit (LCU).
The LCU gives the signal to interrupt the
fluid flow once the bottle is filled to the
calibration mark.

The LCU float switch is adjustable and can
be adapted to the flask in use.


Technical
Data
 
LabCon-UFHD-Module   Operating  Range  

100 to 2000 ml/min

    Connectors Pressure Rear  

One-Touch fitting 6/8 mm
Suitable for use with tubing material: FEP, PFA, Nylon, Polyurethane

    Interface   USB  
    Power supply  

90....264 VAC, 50/60 Hz, max. 150 W

    Dimensions and weight   31 x 23 x 32 cm (W x H x D)
6,6 Kg without accessories
         
Calibration Flask   Model  

Volumetric Flasks, Class A

    Volume   5000 ml
    Accuracy   1,2 ml
    Certificate   Factory calibration certificate
         
LCU   Material  

Body:    Pom Natural white
Switch: Stainless Steel 316 grade SS

    Adjust Range   60 mm
    Cable & Connector  

Cable length: 2 m, Connector:  M12, 5 Pin

         
Internal Flow Reference   Model   HDV-FL
    Range   5 to 1750 ml/min
    Resolution   0.1 ml/min
    Accuracy   1,2 %
         
Environmental conditions   For all devices above   Operating Temperature Range: 0 to 40C
Storage Temperature Range: -40 to 80C
Operating and Storage Humidity: 85% max
relative humidity non-condensing
from 0 to 50C
         
Control PC   Required Operation System   Windows 7
    Required Interface   USB 2.0
 
   
 
 
Home Products Company Support eMail us Address
    Biotech-Lab   About us   Sales & Service   Mail us   IBP Medical GmbH
Ikarusallee 15
30179 Hannover
Germany
+49 511 651647
 
From US 1-866-243-0187
 
    Dialysis Meters   QM-Certificate   FAQ   We want your feedback  
    Pressure & Flow Meters   News   Meter Pick Up Service   Sign our Newsletter  
    Simulator and Tester       Terms & Conditions      
    HDU-Sensors       Warranty      
    HDV-Sensors       Worldwide Distributors      
    Calibration Service       Online Invoice Payment    
    Calibration Systems              
    Dialyser Analyser              
    Customer-Specific Development              

Copyright 2016 IBP Medical GmbH   back to top